The old cast-iron sections are removed, a steel or bimetal radiator is fixed to the wall and connected to the same supply pipes. In a private house with its own boiler there is nobody to get approval from, and the system is drained and refilled on site, without the building manager.
Signs the old radiator has to be replaced
- Damp streaks or rust runs appear between the cast-iron sections: the section seals have dried out.
- The valve at the radiator no longer turns, and the radiator cannot be shut off.
- The radiator stays cold at the bottom even after bleeding, and sludge has built up in it.
- In a bathroom or room renovation you want the radiator somewhere else or swapped for a smaller one.
- There is so much rust on the threads and the body that every movement risks a leak.
From approval to a warm radiator
- Approval from the building manager In a block of flats, radiator replacement must be approved, because the riser up to the first valve in the flat is common property. How to do it is explained in the guide replacing radiators in a flat and approval.
- Shutting off and draining the riser The riser is shut off by the building manager or someone they authorise. In a private house, the system is shut off at the boiler and drained through the drain tap.
- Removing the old radiator The supply pipes are unscrewed or cut, and the cast-iron radiator is lifted off its hooks. It is heavy, so a large radiator is sometimes taken apart by sections in the flat.
- The new radiator, valves and bypass Brackets are fixed to the wall, the radiator is hung and valves are fitted on the supply pipes. If the connection had a bypass pipe, it is kept.
- Filling and bleeding When the riser or the system is filled, the radiator is bled and every connection is inspected until it warms evenly.
A steel panel or bimetal radiator on the building's riser
The size and output of the new radiator are chosen close to the old one. Without a calculation you may not significantly increase the radiator's output or change the connection scheme, because it takes heat from the neighbours on the same riser. Whether a steel panel or bimetal radiator suits the building's system, ask the building manager during the approval: many buildings have their own requirements.
Radiator replacement in a block of flats has to be approved by the building manager; without a calculation you may not significantly increase the output or change the connection scheme (LV portāls e-consultation). Apartment Ownership Law, Section 4: heating elements whose operation depends on common property utilities are common property. Checked on 16.11.2026.
The bypass pipe under the radiator: why it is not cut out
In many Soviet-era buildings the heating is a single-pipe system: water goes along the riser from floor to floor, and the radiator is connected on the side. A short pipe between the radiator's supply pipes, a bypass, lets water keep flowing up the riser even when the radiator is shut off. If the bypass is cut out and valves are fitted, the neighbours below you can be left without heat as soon as you turn off your radiator.
So when a radiator is replaced, the bypass is kept or fitted anew, and the valves go on the radiator's supply pipes, not on the riser. Next time the radiator has to be removed, it can be shut off with its own valves, without draining the riser.
Moving a radiator to another wall
Moving a radiator under another window or to another wall means new supply pipes from the riser and a different connection scheme. In a block of flats it has to be approved in the same way as a replacement, and if the building manager asks, a calculation is needed. In Soviet-era buildings the pipes often pass through the floor slab into the neighbour's flat, so the riser's position usually cannot be moved within one flat.
In a private house moving is simpler: the supply pipes are extended along the wall or in the floor, and the system is bled afterwards. Longer supply pipes also mean more metres of pipe and more work.
How much radiator replacement costs and what makes it dearer
Installing or replacing a radiator is from €75 per radiator: the old one is removed, the new one is mounted and connected to the same supply pipes, filled and bled. The work on new heating supply pipes is priced after inspection. Shutting off the riser through the building manager in a block of flats is extra.
The price goes up with a heavy cast-iron radiator that has to be taken apart and carried down the stairs, rusted threads that have to be cut, new valves and a bypass, and moving. This is labour only; materials are extra. If there is a travel charge, it is stated on the call before the work.
What happens to the neighbours while the riser is empty
While the riser is shut off, the radiators on it are cold on every floor, so warn the neighbours and agree on a day. When the riser is filled, the water comes under pressure, and a weakly tightened connection can start to leak at your place or at the neighbour's below. At that moment someone has to be at the radiator to see it.
If the old supply pipe is so rusted that the thread breaks, the job reaches a section of the riser, and that is common property. In such a case, talk to the building manager before the work.
Sources
- Radiator replacement must be approved by the building manager; the riser up to the first valve is common property; output and scheme do not change without a calculation checked 16 November 2026
- Heating elements are common property if they depend on common property utilities (Section 4) checked 16 November 2026
- Bleeding after filling checked 13 November 2026